Performance of GGBS in Ready Mix Concrete Industry
Loading...
Date
item.page.authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The study is a novel attempt to bridge the gap between theoretical aspects of GGBS based concrete
newlinemixes with the industrial concrete mixes. The study has focused more on to a sustainable concrete
newlinewhich is fulfilling the industrial demands. Since cement being a carbon footprint contributor,
newlineexpects a replacement with the industrial byproducts with cementitious properties such as GGBS,
newlinefly ash, silica fumes and rice husk ash many more. The confident adaptability of these
newlineSupplementary Cementitious Materials in place of cement needs an extensive research work as a
newlinereduced.
newlineThe objectives of the research work not only explore the laboratory-based properties of GGBS as
newlinereplacement to cement in concrete, but also extend its scope of work to industrial needs especially
newlinein the mix proportioning adopted for Ready Mix Concrete. The study has been categorized into
newlinethree important phases.
newlineThe Phase I deals with the study on fundamental foundation for adopting GGBS in place of cement.
newlineThe study has explored vastly the various percentage replacements for cement by GGBS. The
newlineentire process is the optimization of GGBS with respect to water to binder[W/B] ratio. The
newlineoptimization of GGBS replacement was carried out based on the fresh properties, hardened
newlineproperties and durability properties of concrete with GGBS compared to control mix. The study
newlinealso comprises of measuring the slump, air content, temperature setting time along with strength
newlineproperties. The complete study concludes that the replacement up to 50% GGBS seems to be a
newlinesuitable combination with PCE based chemical admixtures. The study also draws the attention
newlinetowards using only GGBS and PCE based admixtures without any additives like alcofine, the
newlinehardened properties explored at 28 days curing period as per BIS standards were extended up to
newline56 days by noticing the significant improvement in the strength properties at that curing period
newlinebeyond which up to 180 days curing period the pattern of graph seems to be flat. This reason
newlinebehind this pattern may be due to the calc