fault tolerant multimodal safety related medical systems

dc.contributor.guideShubhajit Roy Chowdhury
dc.coverage.spatial
dc.creator.researcherLakkamraju Venkata Rama Prasada Raju
dc.date.accessioned2024-01-02T05:40:31Z
dc.date.available2024-01-02T05:40:31Z
dc.date.awarded2019
dc.date.completed2023
dc.date.registered2011
dc.description.abstractThe safety improvements in the medical systems or devices, specifically non-invasive newlinepatient monitoring systems (PMS) and point-of-care (POC) devices of human health monitoring newline(HHMS) systems, are in great need to perform precise measurements of vital parameters with newlineuninterrupted continuous monitoring for diagnosis of significant human health ailments. During newlinecritical or non-critical nursing times, frequent monitoring of short and long-duration measures of newlinevital parameters (like ECG, EEG, Respiratory, SpO2, Blood-pressure, Temperature, etc.) and newlinenon-vital parameters (like Glucose levels, Hemoglobin, Urea in blood, etc.) will allow for better newlinenursing and early detection of diseases like cardiovascular diseases, respiratory diseases, liver newlinedysfunction, diabetes, renal diseases, and other psychological disorders. A non-invasive medical newlineinstrumentation system for accomplishing these tasks must meet several criteria like accuracy newlineand precision of the measurement, reduction of false alarms, effective detection of faults, and newlinefault tolerance to systemic or random failures with an uninterrupted performance during nursing newlinetimes. newlineMany research groups have made many efforts worldwide to make strategies and guidelines newlineand standardize the procedures for medical systems based on safety design approaches to raise newlinealerts for any deviance during non-invasive monitoring of health parameters. In addition, health newlinemonitoring instruments should be portable, low-cost, and reliable over time. Many modes of newlinediagnosis and related instrument maintenance procedures satisfy these criteria. However, most of newlinethem are still in the improvement stage for developing resilient instruments for integrating with newlinecritical auto-robotic surgery instruments with minimal human intervention. newlineSeveral approaches have been proposed, out of which safety-related design approaches like newlineusing 2oo2, 2oo3, 1oo2, etc., along with AI-based data analytics, have the advantage of meeting newlinethese rigorous demands in fundamental safety improvements of Medical Systems. Based
dc.description.note
dc.format.accompanyingmaterialNone
dc.format.dimensions
dc.format.extent157
dc.identifier.urihttp://hdl.handle.net/10603/535768
dc.languageEnglish
dc.publisher.institutionElectronics and Communication Engineering
dc.publisher.placeHyderabad
dc.publisher.universityInternational Institute of Information Technology, Hyderabad
dc.relation
dc.rightsuniversity
dc.source.universityUniversity
dc.subject.keywordEngineering
dc.subject.keywordEngineering and Technology
dc.subject.keywordEngineering Electrical and Electronic
dc.titlefault tolerant multimodal safety related medical systems
dc.title.alternative
dc.type.degreePh.D.

Files

Original bundle

Now showing 1 - 5 of 13
Loading...
Thumbnail Image
Name:
80_recommendation.pdf
Size:
162.92 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
abstract.pdf
Size:
16.84 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
annexures.pdf
Size:
494.73 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
chapter 2.pdf
Size:
447.89 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
chapter 3.pdf
Size:
1.18 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: