newline The study, titled TO COMPARE EFFICACY AND PREDICTABILITY OF SYNTHETIC HYDROXYAPATITE VERSUS A COMMERCIALLY AVAILABLE BOVINE HYDROXYAPATITE IN LATERAL WALL SINUS AUGMENTATION- A RANDOMISED CLINICAL STUDY
newlinewas undertaken to answer the following question: Indigenously prepared Hydroxyapatite bone graft can provide a solution for all grafting needs in terms of cost, ease of procurement, results and patient comfort, however are these products better than commercially available bovine Hydroxapatite bone graft? In the study conducted, both the bone graft substitutes have shown good bone formation. The new bone formation was at the rate of 60% in Bio-oss and 100% in case of G-bone but this difference is attributed due to delayed bone formation with Bio-oss, In the study both the bone graft substitutes have shown good bone formation. The new bone formation was at the rate of 60% in Bio-oss and 100% in case of G-bone but this difference is attributed due to delayed bone formation with Bio-oss, which has been discussed above. biopsies were taken at 6 months, hence the difference in bone formation. When it comes to discussing other parameters, such as residual bone graft, in Bio-Oss it was upto 70%, whereas in the G-bone it was 100%.