Non-conventional plasma machining and nano-polishing of optics
Loading...
Date
item.page.authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
In this study, a medium-pressure plasma flow system was designed and developed for plasma
machining of fused silica optics. The results showed that the plasma flow system can be used for
long machining times (more than 60 minutes) with a material removal rate that is 300% higher
than the earlier studied confined system. The study also found that there is an improvement in
surface integrity, as identified by Raman microscopy, and surface topography, as determined by
the 3D profiler. In this study, a non-invasive method was developed using an optical emission
spectrometer to predict MRR during polishing. The Comsol® simulation was utilized to
optimize the plasma chamber configuration, resulting in a custom-made chamber with a Vshaped
groove that showed uniform reactive radical distribution for polishing free-form optics.
Confocal Raman microscopy was used to quantify the depth of damage on ground fused silica.
This methodology was adopted to optimize the rotary ultrasonic machining parameters for
shaping fused silica hemispherical resonator shells (HRG). To investigate the cause of Ring
Laser Gyroscope device failure, a photoluminescence spectrometer was utilized for analysis and
verification. Furthermore, the SSD depth at the nanometer scale was quantified for the ultrasmooth
prism substrate using Secondary Ion Mass Spectrometer (SIMS). A process flow was
established for removing 350 nm depth of material without affecting the surface finish of the
ultra-fine fused silica substrate, using plasma processing followed by chemical leaching to
enhance the surface integrity of the prism substrate. In this study, a non-invasive method was
developed using an optical emission spectrometer to predict MRR during polishing. The
Comsol® simulation was utilized to optimize the plasma chamber configuration, resulting in a
custom-made chamber with a V-shaped groove that showed uniform reactive radical distribution
for polishing free-form optics. Confocal Raman microscopy was used to quantify the depth of
damage on ground fused silica. This methodology was adopted to optimize the rotary ultrasonic
machining parameters for shaping fused silica hemispherical resonator shells (HRG). To analyze
and verify the plausible mechanism of Ring Laser Gyroscope device failure, a
photoluminescence spectrometer was used. Furthermore, the SSD depth at the nanometer scale
was quantified for the ultra-smooth prism substrate using Secondary Ion Mass Spectrometer
(SIMS). A process flow was established for removing 350 nm depth of material without
affecting the surface finish of the ultra-fine fused silica substrate, using plasma processing
followed by chemical leaching to enhance the surface integrity of the prism substrate. This study
compares plasma etching versus wet chemical etching and suggests plasma machining as a safer
alternative.