Development of a Vanadium Redox Flow Battery Through Novel Flow Field Design and Cost Competitiveness Analysis
Loading...
Date
item.page.authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The burning of fossil fuels for vehicle propulsion and power generation has been degrading the environment for a long time. There is a growing demand for energy which has to be satisfied through the use of decarbonized and environmentally friendly renewable energy sources (RESs) for a better cum sustainable future. Government initiatives like ensuring an alternative to fossil fuels by 2050 have already been initiated.
newlineRenewable energy sources such as wind and solar are intermittent and need large scale electrochemical energy storage (EES) alternatives. An energy storage system must be carefully integrated into the grid in order to store the excess energy harnessed during times of low demand and make it available on-demand. It must ensure adequate storage capacity, sustain a high number of charge/discharge cycles, offer flexible operation with utmost safety, and exhibit reasonable capital investment (CAPEX) and operating expenses (OPEX) in order to be technically and economically competitive.
newlineFlow Battery (FB) is a highly promising upcoming technology among Electrochemical Energy Storage (ECES) systems for stationary applications. The Vanadium Redox Flow Battery (VRFB) is the most promising and developed among the FBs, due to its realizable power and energy density levels, higher efficiency, and very long life. Flow field design is an effective way to improve the battery performance without incurring substantial additional costs. The flow characteristics of the electrolyte have a direct impact on the mass transfer process on the felt electrode surface, consequently influencing the overall performance of the VRFB battery. Lot of research activities are in progress to design and optimize the flow fields in order to improve the performance of VRFB. The most frequently used channel patterns are flow-through (without a flow field) and flow-by (serpentine, interdigitated, parallel, spiral, and their variants). Though being used widely, each of them share their set of drawbacks. Also, it can be inferred from literature.