Heat Transfer Analysis of a Fin-tube Heat Exchanger using Shearthinning Fluid and Winglet Type Vortex Generators

dc.contributor.guideDalal, Amaresh
dc.creator.researcherKumar, Dheeraj
dc.date.accessioned2024-06-19T11:04:13Z
dc.date.available2024-06-19T11:04:13Z
dc.date.awarded2024
dc.date.completed2024
dc.date.registered2020
dc.description.abstractThe present thesis work investigated the effect of various shapes of winglets, such as delta winglet pairs (DWP), rectangular winglet pairs (RWP), and curved rectangular winglet pairs (CRWP), on the flow behavior of an aqueous solution of carboxymethylcellulose (CMC) through a rectangular channel with and without the inbuilt cylinders. Threedimensional numerical simulations were carried out for a range of Reynolds numbers (50-200) using aqueous carboxymethylcellulose, commonly known as non-Newtonian shear-thinning fluid as a working fluid. Nusselt number (Nu), friction factor (f), and the combined effect of Nu and f, commonly known as quality factor (Qf), were calculated and compared for each case. Additionally, the comparison is also made with the base channel considering a dimensionless number (η) defined as (Num/Nuo)*(fo/f)0.33. As well, an investigation was conducted into the impact of attack angle, winglet placement, and tube placement on the thermohydraulic performance of the channel. The fintube heat exchanger (FTHE) performance parameters were effectively compared and evaluated using an aqueous solution of CMC and water. It was discovered that incorporating DWP in FTHE improves overall performance compared to RWP. Still, when only heat transfer applications are considered, RWP outperforms DWP. When comparing the thermohydraulic performance, the use of CRWP is unequivocally superior to RWP. The former option provides a more efficient and effective means of achieving the desired outcomes. Reducing the attack angle improves performance up to a limit, but further decrease reduces performance. Utilizing an aqueous solution of CMC as a working fluid has been established as a practical approach to augment heat transfer while simultaneously reducing pressure drop. Based on the thorough evaluation of the overall performance, it is evident that FTHE with winglets significantly outperforms the base channel. Staggered tube configurations of FTHE show better thermal performance than inline tube configurations. They generate higher values of critical parameters such as Nu, f, and Qf, which enhances the efficiency and effectiveness of relevant applications.
dc.format.accompanyingmaterialNone
dc.identifier.urihttp://hdl.handle.net/10603/572207
dc.languageEnglish
dc.publisher.institutionDEPARTMENT OF MECHANICAL ENGINEERING
dc.publisher.placeGuwahati
dc.publisher.universityIndian Institute of Technology Guwahati
dc.rightsself
dc.source.universityUniversity
dc.subject.keywordEngineering
dc.subject.keywordEngineering and Technology
dc.subject.keywordEngineering Mechanical
dc.titleHeat Transfer Analysis of a Fin-tube Heat Exchanger using Shearthinning Fluid and Winglet Type Vortex Generators
dc.type.degreePh.D.

Files

Original bundle

Now showing 1 - 3 of 3
Loading...
Thumbnail Image
Name:
01_fulltext.pdf
Size:
14.69 MB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
04_abstract.pdf
Size:
131.86 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
80_recommendation.pdf
Size:
387.98 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: