Design and Implementation of a Low noise Low power Bio potential Amplifier for Biomedical Applications

dc.contributor.guideNaik Amisha
dc.coverage.spatial
dc.creator.researcherAdesara Ankit
dc.date.accessioned2022-06-07T05:41:49Z
dc.date.available2022-06-07T05:41:49Z
dc.date.awarded2021
dc.date.completed2021
dc.date.registered2014
dc.description.abstractnewline The continuous real-time monitoring of diverse physical parameters using bio-signals like ECG and EEG requires the bio-medical sensors for capturing those signals. Such a sensor consists of an analog front-end unit for which the operational transconductance amplifier (OTA) is an essential block. Along with noise and power, the parameters like CMRR, input impedance, DC offset newlineand output ripple must be taken into consideration while designing as they equally affect the overall performance of amplifier. newline newline In this work, the novel chopper-stabilized bio-potential amplifier is proposed. The chopper-stabilization method is used, by judiciously selected chopping frequency, to reduce the DC electrode offset and flicker noise. Further, the operational transconductance amplifier (OTA) is equipped with a additional circuit in form of forward path to enhance the input impedance without consuming extra power. In addition to this, the ripple reduction technique is employed at the output branch of the operational transconductance amplifier. The designed amplifier can be used for various applications like portable devices, wearable electronics and health care devices newline newline The major challenge while designing was to maintain the balance in performance in terms of noise and power due to the existence of a trade-off between them. The specifications have been carefully chosen after detailed study of ECG and EEG recording systems for the bio-potential amplifier as it processes very low amplitude and frequency bio-signals, not only that the Layout design was very crucial due to issues of matching of various devices as it also affects overall circuit performance newline newline The designed amplifier consumes 5.5 µW power with the mid-band gain of 40 dB. The passband for the designed amplifier is 0.1 Hz to 1 KHz. The input impedance is likewise boosted with the proposed method up to 200 Mand#8486;. The noise is 42 nV/and#8730;Hz with CMRR of 82 dB. All the pre- and post-layout simulations are carried out using 180nm technology node. newline newline newline
dc.description.note
dc.format.accompanyingmaterialDVD
dc.format.dimensions
dc.format.extent
dc.identifier.urihttp://hdl.handle.net/10603/384688
dc.languageEnglish
dc.publisher.institutionInstitute of Technology
dc.publisher.placeAhmedabad
dc.publisher.universityNirma University
dc.relation
dc.rightsuniversity
dc.source.universityUniversity
dc.subject.keywordAmplifier
dc.subject.keywordbio-signals
dc.subject.keywordtransconductance amplifier
dc.titleDesign and Implementation of a Low noise Low power Bio potential Amplifier for Biomedical Applications
dc.title.alternative
dc.type.degreePh.D.

Files

Original bundle

Now showing 1 - 5 of 17
Loading...
Thumbnail Image
Name:
01_title_page.pdf
Size:
210.89 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
02_certificate.pdf
Size:
51.17 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
03_declaration.pdf
Size:
48.66 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
04_acknowledgement.pdf
Size:
655.35 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
05_abstract.pdf
Size:
549.23 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: