Study on characteristics of Polymeric Housed Surged Arrester

Abstract

Surge arresters play a vital role in protecting the equipment in the power system and also in newlineinsulation coordination. Major changes in the surge protection have taken place for the last newline40 years. During this period metal oxide surge arresters has evolved and it has excellent newlinesurge protection characteristics due to its non-linear nature of V-I characteristics. newlinePresently the metal oxide surge arresters are with either ceramic or polymeric housing. The newlinepolymeric housed arresters have replaced a large no of ceramic housed arresters especially newlinein distribution systems. The polymeric housed surge arresters have several advantages to newlinetheir credit than the ceramic housed surge arresters. The major advantage of polymeric newlinehoused surge arrester is that it exhibits superior hydrophobic surface. Due to this the newlinepollution deposit and dry band flashover are reduced compared to ceramic housed newlinearresters. In the ceramic housed arresters, the surface is less hydrophilic compared to the newlinehydrophobic property of polymeric housing. In spite of all the advantages of polymeric newlinehoused surge arresters, they suffer a major drawback of ageing. The problem of ageing of newlinepolymeric housed surge arresters is still under study and research. newlineThe gap between the housing and the element column allows the dynamic voltage changes newlinedue to dry band arcing to get coupled and it was observed by earlier researchers that this newlinecoupling affects the voltage distribution along the length of the arrester causing heating of newlinethose arrester blocks which share higher voltages. newlineEven though pollution flashover may not occur in polymeric housed arresters the dry band newlinearcing in the form of scintillations appear on the surface. These scintillations though they newlineare of low current; due to their high frequency behaviour they may couple to inner newlineelements. The gap between the inner arrester elements and the housing is small compared newlineto that in ceramic housed arresters. Due to this a stronger coupling may exist which causes newlinethe high-frequency scintillations to affect the voltage distribution dynamically and hence newlinehigher current through the arrester blocks caused resulting in ageing of the arrester. newline newline2 newlineIn the present work, the study on various characteristics of polymeric housed arresters has newlinebeen chosen with due considerations to the above problems which may be the cause for the newlineageing of the polymeric housed surge arresters. The major cause for the ageing of the newlinearrester is the temperature rise. The temperature of the arrester may rise due to various newlinereasons, like an increase in leakage current flowing under normal operating conditions, due newlineto rise in temperature of the atmosphere or due to frequently occurring surges. Considering newlinethe above facts, the simulation studies study was carried out to analyse the leakage current newlineand the effect of temperature on the leakage current. The study was carried out both by newlineconducting experiments and by simulating the electrical characteristics using MATLAB. newlineExperiments were carried out on a block of ZnO for studying the leakage current behaviour newlinewith varying voltage and temperature. newline

Description

Keywords

Citation

item.page.endorsement

item.page.review

item.page.supplemented

item.page.referenced