Study on the Bond Slip Behaviour of Geopolymer and Conventional Concretes after Exposure to Different Temperatures

dc.contributor.guideMathew, George
dc.coverage.spatial
dc.creator.researcherSuresh Babu, N
dc.date.accessioned2023-06-26T11:29:54Z
dc.date.available2023-06-26T11:29:54Z
dc.date.awarded2023
dc.date.completed2022
dc.date.registered2016
dc.description.abstractConcrete is the most widely used construction material across the globe. newlineBond-slip behaviour of steel in concrete is a major factor for the structural design of newlineRCC members. newlineOn many occasions, concrete is exposed to elevated temperatures like that of newlinefire, furnaces, etc. It is a proven fact that, the strength and other performance of newlineconcrete is affected when it is exposed to elevated temperatures. So it is vital to newlineunderstand the behaviour of concrete and structural members after exposure to newlineelevated temperatures. newlineThe research in the area of geopolymer concrete has gained momentum in the newlinerecent years primarily due to its role in reducing greenhouse gas emission compared newlinewith OPC concrete. Studies in the past confirm that geopolymer concrete shows newlinebetter performance in terms of strength and durability when compared with OPC newlineconcrete. newlineMany researchers reported the bond-slip behaviour of OPC concrete both at newlineambient temperature and after exposure to elevated temperatures. However, limited newlineinformation is available about the bond-slip behaviour of geopolymer concrete under newlinethe said temperature exposure conditions. newlineHence, it has been proposed to study the bond-slip behaviour of geopolymer newlineconcrete, at ambient temperature and after exposure to elevated temperatures and to newlinecompare the properties with those of corresponding conventional concretes. A newlinestandard pull-out test, as per Indian standard specifications, was conducted for the newlinepresent study. For the geopolymer concrete, the aluminosilicate material considered newlinefor the present study was fly ash and the alkali activators were a combination of newlinesodium silicate and sodium hydroxide.This study considers the partial replacement of GGBS so newlinethat the geopolymer concrete would not require temperature curing. newline newline
dc.description.note
dc.format.accompanyingmaterialDVD
dc.format.dimensions
dc.format.extentxvi,152
dc.identifier.urihttp://hdl.handle.net/10603/494371
dc.languageEnglish
dc.publisher.institutionDepartment of Safety and Fire Engineering
dc.publisher.placeCochin
dc.publisher.universityCochin University of Science and Technology
dc.relation
dc.rightsuniversity
dc.source.universityUniversity
dc.subject.keywordBond-Slip Behaviour
dc.subject.keywordCasting and Curing
dc.subject.keywordEngineering and Technology
dc.subject.keywordGeo-Polymer Concrete
dc.subject.keywordOPC concrete
dc.subject.keywordSafety and Fire Engineering
dc.titleStudy on the Bond Slip Behaviour of Geopolymer and Conventional Concretes after Exposure to Different Temperatures
dc.title.alternative
dc.type.degreePh.D.

Files

Original bundle

Now showing 1 - 5 of 12
Loading...
Thumbnail Image
Name:
01_title.pdf
Size:
263.74 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
02 -preliminary pages.pdf
Size:
446.55 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
03_content.pdf
Size:
187.41 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
04_abstract.pdf
Size:
190.75 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
05_chapter1.pdf
Size:
385 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: