Experimental and numerical investigations of flow through an annular diffuser with and without struts

dc.contributor.guideMahalakshmi N Ven_US
dc.coverage.spatialExperimental and numerical investigations of flow through an annular diffuser with and without strutsen_US
dc.creator.researcherPrakash Ren_US
dc.date.accessioned2014-03-11T08:28:25Z
dc.date.available2014-03-11T08:28:25Z
dc.date.awarded31/10/2013en_US
dc.date.completed01/10/2013en_US
dc.date.issued2014-03-11
dc.date.registeredn.d.en_US
dc.description.abstractAn exhaust diffuser is a critical component of gas turbine applied to newlineboth the propulsion and power system applications. The exhaust diffuser of an newlineindustrial gas turbine recovers the static pressure by decelerating the turbine newlinedischarge flow. This allows the turbine to be operated at an exhaust pressure newlinelower than the atmospheric one, thus increasing the turbine work. This makes newlinethe diffuser a critical element in the turbomachine environment in terms of newlineefficiency and stability. newlineIn the present work, experimental and numerical investigations newlinehave been carried out to study the effect of the struts on the flow structure and newlinethe performance of the diffusers. The strut design that has the potential to newlinechange the diffuser dynamics was tested. Two types of struts were used newlinenamely baseline struts and tapered struts. newlineThe objective of the present work is to provide an improved newlineunderstanding of flow passing over struts in an annular diffuser. The flow newlinethrough the diffuser with and without struts was studied. Experiments were newlineconducted for three different types of configurations namely diffuser without newlinestruts, with baseline struts and with tapered struts. A low speed sub sonic newlinewind tunnel was used to conduct the experiments. A Five-hole pitot pressure newlineprobe with a digital manometer was used to measure pressure, and a newlineDANTEC Dynamics make constant temperature anemometer with X-probe was used to measure mean velocity, and turbulence level in axial and radial newlinedirections. Measurements were taken at a number of radial positions across newlinethe annulus, and at some circumferential positions at each axial location along newlinethe diffuser. The results suggest that tapered design perform better than the newlinebaseline design.en_US
dc.description.noteen_US
dc.format.accompanyingmaterialNoneen_US
dc.format.dimensions21cmen_US
dc.format.extentxvi, 136p.en_US
dc.identifier.urihttp://hdl.handle.net/10603/17398
dc.languageEnglishen_US
dc.publisher.institutionFaculty of Mechanical Engineeringen_US
dc.publisher.placeChennaien_US
dc.publisher.universityAnna Universityen_US
dc.relationp.127-134en_US
dc.rightsuniversityen_US
dc.source.universityUniversityen_US
dc.subject.keywordAnnular diffuseren_US
dc.subject.keywordMechanical engineeringen_US
dc.subject.keywordStrutsen_US
dc.titleExperimental and numerical investigations of flow through an annular diffuser with and without strutsen_US
dc.title.alternativeen_US
dc.type.degreePh.D.en_US

Files

Original bundle

Now showing 1 - 5 of 15
Loading...
Thumbnail Image
Name:
01_title.pdf
Size:
87.28 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
02_certificates.pdf
Size:
1.94 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
03_abatract.pdf
Size:
7.68 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
04_acknowledgement.pdf
Size:
5.91 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
05_contents.pdf
Size:
23.95 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: