Investigation on Strength Durability and Antimicrobial Resistance of Cementitious Systems for use in Marine Conditions
Loading...
Date
item.page.authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Microbial-induced corrosion (MIC) is a problem caused by acidophilic
newlinemicroorganisms that deteriorate concrete. The reinforced concrete (RC)
newlinestructures built in marine environment are severely impacted by MIC, costing
newlinebillions of dollars in maintenance and repairs. Better resistance to MIC has
newlinebeen demonstrated by the modification of concrete materials through the
newlineaddition of chemical and mineral admixtures. Furthermore, cathodic protection
newlinesystem is a well-established method for corrosion protection in steel structures
newlineexposed to marine environments and have recently been extended to RC
newlinestructures. This study evaluated the performance of chemical admixtures in
newlinecementitious systems based on their (a) strength, (b) durability, and (c)
newlineantimicrobial resistance to provide protection against MIC. In addition, the
newlinestudy attempted to assess the performance of a sacrificial anode cathodic
newlineprotection (SACP) system for RC structures exposed to a simulated marine
newlineenvironment to control corrosion of steel rebar due to MIC. Based on the
newlinefindings of the present study, it can be concluded that incorporation of a sodium
newlinenitrite-based corrosion inhibiting admixture (SNI) improves the antimicrobial
newlineperformance of cement mortar in addition to its mechanical and durability
newlineperformances. Hence, a 2% by weight of binder dosage of SNI is
newlinerecommended for enhanced antimicrobial resistance of concrete structures in
newlinethe marine environment. In addition to the SNI, the SACP system can be
newlineinstalled on RC structures as a second line of defence to further improve
newlinecorrosion resistance. However, the combined mechanism of the SNI and
newlineSACP system in RC structure has scope for further research.
newline