Design and Fabrication of A Head Phantom for Dosimetric Evaluation of Radiotherapy Treatment Plans

dc.contributor.guideRaghuram K Nair
dc.coverage.spatial
dc.creator.researchershaiju VS
dc.date.accessioned2021-12-30T05:00:51Z
dc.date.available2021-12-30T05:00:51Z
dc.date.awarded2021
dc.date.completed2021
dc.date.registered2014
dc.description.abstractAbstract newline newlineThe study aims to design and fabricate a Polymethyl methacrylate (PMMA) head phantom for the dosimetric evaluation of the radiotherapy treatment plans. A comparison study has also been conducted between Anisotropic Analytical Algorithm (AAA) and Acuros XB algorithm for the clinical radiation treatment plans of 15 patients using different ion chamber detectors. A dosimetric study related to the presence of Onyx material during the planning of arteriovenous malformations (AVMs) of the brain was also done. Variation of measured dose over the planned dose using detectors CC13, CC01, A14SL and FC65 and results were compared with AAA and Acuros XB algorithms. The range in percentage of dose deviation for 15 Volumetric Arc Therapy (VMAT) plans for head phantom was found to be 0.26 to 1.92 when compared with the ArcCheck phantom (-0.38 to 2.54). The difference in dose deviation between the phantoms was statistically significant with p-value newline0.007, and the results with head phantom showed more agreement with the calculated values of dose. The mean percentage dose variation of VMAT plans calculated using Acuros XB algorithm and measured in the head phantom was found to be statistically significant with a p-value of 0.001 except for chambers A14SL and CC01. The integral dose calculations reveal that there is a dose discrepancy due to the presence of Onyx related artefacts. The results show that for the proximal ring structure shows higher dose deviations for Monte Carlo (-4.02%) when compared to Acuros XB (-2.98%) and AAA (- newline2.49%). The in-house designed and fabricated head phantom can be used for point dose and fluence measurements in Patient-Specific Quality Assurance (PSQA) for treatment plans. The study concludes that the CT images of the detectors give more artefacts/heterogeneity with volume, which can cause significant variations in calculated dose using Acuros XB. newline
dc.description.note
dc.format.accompanyingmaterialNone
dc.format.dimensions
dc.format.extentxvii 175
dc.identifier.urihttp://hdl.handle.net/10603/353212
dc.languageEnglish
dc.publisher.institutionDepartment of Science
dc.publisher.placeChennai
dc.publisher.universityMeenakshi Academy of Higher Education and Research
dc.relation
dc.rightsuniversity
dc.source.universityUniversity
dc.subject.keywordClinical Medicine
dc.subject.keywordClinical Pre Clinical and Health
dc.subject.keywordRadiology Nuclear Medicine Medical Imaging
dc.titleDesign and Fabrication of A Head Phantom for Dosimetric Evaluation of Radiotherapy Treatment Plans
dc.title.alternative
dc.type.degreePh.D.

Files

Original bundle

Now showing 1 - 5 of 13
Loading...
Thumbnail Image
Name:
01_title.pdf
Size:
192.75 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
02_certificate.pdf
Size:
303.84 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
03_declaration.pdf
Size:
188.59 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
04_chapter 1.pdf
Size:
2.28 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
05_chapter 2.pdf
Size:
2.03 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: