Experimental and CFD analysis on the thermo hydraulic performance of a corrugated louvered fin and flat tube compact heat exchanger
Loading...
Date
item.page.authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
One of the important aspects of any heat exchanger is to increase the
newlinerate of heat exchange between two streams of fluids. When one stream of the
newlineflowing fluid is gas and the other is a liquid, the heat transfer surface on the
newlinegas side needs to have a much larger surface area, as it is well known that the
newlineheat transfer co-efficient for gases is much lower than that for liquids. A heat
newlineexchanger having a surface area density greater than about 700m2/m3is quite
newlinearbitrarily referred to as a compact heat exchanger. The heat transfer
newlineco-efficient of the extended surfaces may be higher or lower than that of the
newlineunfinned surfaces. The louvered fins increase both the surface area and the heat transfer co-efficient. They are available in a wide variety of
newlineconfigurations of the heat transfer matrix. Their heat transfer and pressure
newlinedrop characteristics are very important, and hence, the extensive studies were
newlinedone on louvered fin heat exchangers by various researchers. In the present work, an experimental investigation was carried out to
newlineanalyze the heat transfer and pressure drop characteristics of a corrugated
newlinelouvered fin and flat tube compact heat exchanger used as a radiator in an
newlineinternal combustion engine. Experiments were conducted by positioning the
newlineradiator in an open-loop wind tunnel. Hot water at 90°C was supplied through the radiator, and the air was
newlinemade to flow across the radiator at atmospheric temperature. During the
newlineexperiment the mass flow rate of water was varied from 0.075 to 0.135
newlinem3/min and the frontal air velocity was varied from 2.5 m/s to 7.5 m/s. A total
newlineof 24 sets of air and water flow rate combinations were tested, and the
newlinetemperature and pressure drops of the air and water were acquired. Using
newlinethese experimental results, the influence of the overall heat transfer
newlineperformance of the heat exchanger due to the effects of the mass flow rate of
newlinewater in the tube side was investigated.
newline