In recent days, low rise buildings are being replaced with high rise buildings,
newlineespecially in rural areas, to accommodate many people in a single plot area as the
newlinepopulation demands. Irrespective of the aesthetic look, the aerodynamic performance
newline(reduction in aerodynamic coefficients and vortex shedding magnitude along with
newlineheight) of unconventional plan shaped buildings like setback structures play a vital
newlinerole in reducing wind pressure and ground-level winds; compared to conventional
newlinebuildings. Available wind code standards provide wind pressure and aerodynamic force
newlinecoefficients only for regular-plan-shaped conventional buildings for a certain angle of
newlineincidences (AOIs). Similarly, the wind flow field around the building should also be
newlineconsidered, which is, unfortunately, not discussed in the wind code recommendations.
newlineHence wind flow behaviour study on and around these buildings receives more attention
newlinefrom urban planners, architects, and wind engineers to ensure safety and comfort.
newlineIn this study, a 210m setback building is geometrically scaled down to 1:300 with
newlinea blockage ratio, 2.3%. The setback building model (H=0.7m) is tested under open
newlineterrain wind flow (UMean =13.6 m/s and T.I =10%) to measure mean and fluctuating
newlinepressures. The CFD simulation (in ANSYS Fluent 18.0) re-creates the atmospheric and
newlinewind tunnel environment following the turbulence parameters and artificial sand grain
newlineroughness. The Improved Delayed Detached Eddy Simulation (IDDES) turbulence
newlinemodel is chosen for the CFD simulation after comparing eight turbulence models by
newlineexamining six variables. The pressure coefficients are acquired from 22 AOIs (19
newlineangles of the range 0_ _ 5_ _ 90_ and 3 special angles: 33_, 56.5_ and 87_). The
newlinepressure variations were measured throughout the perimeter of the model at eight
newlinedifferent heights for all 22 AOIs. The CFD mean and rms pressure coefficients for
newline0_, 45_ and 90_(lower, middle and upper bound angles) validated with wind tunnel
newlineresults showed a good agreement. A maximum pressure deviation of 18