Investigations on box type Configuration of roof slab for Prototype fast breeder reactor
Loading...
Date
item.page.authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The roof slab which forms the top shield of the nuclear reactor
newlinesupports all the components of the reactor Roof slab is essentially a box
newlinestructure with top and bottom plates interconnected by vertical shells and
newlineradial stiffeners welded to them It provides biological and thermal shielding
newlinein the top axial direction of the reactor The diameter and height of the roof
newlineslab in the 500 MWe Prototype Fast Breeder Reactor PFBR are 12 9m and
newline1 8m respectively PFBRs are designed based on the Operating Basis
newlineEarthquake OBE and Safe Shutdown Earthquake SSE which are
newlinecategorized under level A and level D loadings respectively
newlineThis dissertation investigates the structural integrity of the roof slab
newlineof 500MWe PFBR under static and dynamic including seismic loading
newlineconditions The primary objective of this research work is to predict the
newlinestructural integrity of the roof slab of PFBR by performing numerical and
newlineexperimental analysis on scaled down model of roof slab for design
newlineoptimization considering static and dynamic loading conditions
newlineA detailed literature survey has been carried out to identify the
newlineresearch approach to accomplish the objective Since the roof slab under
newlineconsideration is a massive structure weighing 155 tonnes experimental
newlineanalysis using this huge structure calls for larger laboratory space higher
newlineloading capacity huge test structure and high cost necessitating the adoption
newlineof scaling down approach
newline
newline