Modelling and analysis of metallic particle contamination in gas insulated substation under pure sf6 and sf6+n2 gas mixtures

dc.contributor.guideKamakshaiah, Sen_US
dc.contributor.guideAmarnath, Jen_US
dc.coverage.spatialElectrical Engineeringen_US
dc.creator.researcherPadmavathi, Den_US
dc.date.accessioned2012-09-03T10:34:29Z
dc.date.available2012-09-03T10:34:29Z
dc.date.awarded2011en_US
dc.date.completedNovember, 2011en_US
dc.date.issued2012-09-03
dc.date.registeredn.d.en_US
dc.description.abstractCompressed Gas Insulated Substations (GIS) and Transmission Lines (CGIT) basically consist of a conductor supported on insulator inside an enclosure, which is filled with SF6 gas. As one is aware of the attractive features of a Gas Insulated Substation (GIS), they also suffer from certain drawbacks. One of them is the outage due to seemingly innocuous conducting particles. Flash over in a GIS is, in general, associated with longer outage times and greater costs than in a conventional air insulated substation. Sulphur hexafluoride (SF6) widely used in Gas insulated substations due to its high dielectric strength and good arc interruption properties. However, SF6 gas has been found to be a green house gas that causes global warming. Among the environmentally benign gases, alternative to SF6 gas, the SF6- N2 gas mixtures is regarded as one of the most attractive gases for the same setup used for SF6, because of the synergetic effect in electrical insulation performance. A study of CIGRE group suggests that 20% of failures in GIS are due to the presence of various conducting contaminants in the form of loose particles which are produced by the abrasions between components during assembly and operation. The presence of metallic contaminant in compressed GIS is a major threat when operated at higher fields. If the effect of these can be reduced, the reliability of GIS can be improved.Therefore, there is an increasing interest in the possible application of mixtures of SF6 and other gases to reduce insulation cost and to minimize the possible hazard of particle-initiated breakdown. Many researchers have studieTherefore, there is an increasing interest in the possible application of mixtures of SF6 and other gases to reduce insulation cost and to minimize the possible hazard of particle-initiated breakdown. Many researchers have studieWhen metallic particles are present in the SF6 gas and the voltage is applied between the electrodes.en_US
dc.description.noteReferences p.447-461, Appendices p.436-445en_US
dc.format.accompanyingmaterialNoneen_US
dc.format.dimensions-en_US
dc.format.extentxiii, 445p.en_US
dc.identifier.urihttp://hdl.handle.net/10603/4520
dc.languageEnglishen_US
dc.publisher.institutionFaculty of Electrical Engineeringen_US
dc.publisher.placeKukatpallyen_US
dc.publisher.universityJawaharlal Nehru Technological Universityen_US
dc.relation108en_US
dc.rightsuniversityen_US
dc.source.inflibnetINFLIBNETen_US
dc.subject.keywordElectrical Engineeringen_US
dc.titleModelling and analysis of metallic particle contamination in gas insulated substation under pure sf6 and sf6+n2 gas mixturesen_US
dc.title.alternative-en_US
dc.type.degreePh.D.en_US

Files

Original bundle

Now showing 1 - 5 of 18
Loading...
Thumbnail Image
Name:
01_title.pdf
Size:
78.71 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
02_certificate.pdf
Size:
93.8 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
03_declaration.pdf
Size:
74.23 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
04_abstract.pdf
Size:
114.97 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
05_acknowledgements.pdf
Size:
60.12 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: