Development and application of novel bioanalytical methods for the formulation vehicles used in preclinical formulations
Loading...
Date
item.page.authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Bioanalytical Method development and validation for formulation excipients:In the present thesis, three formulation excipients namely polyethyleneglycol 400, cremophor EL and solutol HS15 that are most frequently used to prepare formulations of new chemical entities (NCE) in drug discovery were studied to establish pharmacokinetic profile/PK parameters after intravenous and oral administration to male sprague dawley rats. Novel bioanalytical methods were developed and validated for the selected excipients. It was found that all the three excipients have clear elimination phase in intravenous route of administration and absorption phase followed by elimination phase in oral route of administration. Spiky plasma concentration profiles were not observed for any of the excipients selected for thesis. Monitoring the excipient levels along with the NCE studied will help to take a decision on the spiky plasma concentration profiles. Identification and reduction of ion suppression effects (Matrix effect) caused by formulation excipients:
The developed bioanalytical methods helped to establish the plasma concentrations of the formulation excipient after intravenous and oral administration to sprague dawley rats. Ion suppression effects caused by the formulation excipients (polyethyleneglycol 400, cremophor EL, solutol HS15) on standard compounds with differing lipophilicities were studied with known concentrations of excipient spiked to plasma. Sample preparation procedures such as protein precipitation and liquid liquid extraction were tested. Different mobile phase combinations, different ionisation sources were tested to reduce the suppression effects caused by formulation excipients. For all the three excipients studied it was found that liquid liquid extraction with hexane/TBME totally reduced the ion suppression effects, whereas for cremophor EL using atmospheric pressure chemical ionisation helped in reducing the ion suppression effects.