Design and analysis of a modified multiport interleaved flyback converter operated photovoltaic shunt active power filter pv shapf

dc.contributor.guideBalamurugan R
dc.coverage.spatialDesign and analysis of a modified multiport interleaved flyback converter operated photovoltaic shunt active power filter pv shapf
dc.creator.researcherRadhamani R
dc.date.accessioned2025-11-07T10:45:59Z
dc.date.available2025-11-07T10:45:59Z
dc.date.awarded2025
dc.date.completed2025
dc.date.registered
dc.description.abstractIn recent days an increased concern over the quality of the power newlinedelivered by the utility as it relates to the non-linear load. Non-linear loads newlinecause deviations from the ideal sinusoidal current and voltage waveforms. newlineNon-sinusoidal power line currents can lead to system noise and voltage newlineharmonics. Harmonic current in the power line can have a significant impact newlineon transformer function, medical apparatus, security systems, and control newlinesystems. Therefore, the quality of electricity for consumers has declined. newlineIndustrial users are concerned about a potential decline in power quality. newlinePower quality concerns are governed by standards set by IEEE and IEC. newlineThere has been a significant amount of research focused on enhancing newlineconsumer power quality due to the ongoing decline in power quality in the newlineelectrical power network. In recent times, several techniques have emerged to newlinereduce voltage distortions caused by non-linear loads. Passive and active newlinepower filters are enhanced to reduce current and voltage distortions. The newlineparameters of R, L, and C in a passive filter are determined by the specific newlineharmonic range that needs to be adjusted. The use of passive power filters newlineleads to the following issues: elimination of harmonics depends on the aging newlineof the passive components, use of L and C components may lead to resonance newlinein the power line, reconfiguration of filter needs complicated design and newlinecompensating only a specific harmonic order. newline
dc.description.note
dc.format.accompanyingmaterialNone
dc.format.dimensions21cm
dc.format.extentxvi,177p.
dc.identifier.researcherid
dc.identifier.urihttp://hdl.handle.net/10603/672110
dc.languageEnglish
dc.publisher.institutionFaculty of Electrical Engineering
dc.publisher.placeChennai
dc.publisher.universityAnna University
dc.relationp.169-176
dc.rightsuniversity
dc.source.universityUniversity
dc.subject.keywordActive Power Filter
dc.subject.keywordPhotovoltaic
dc.subject.keywordVoltage Source Inverter
dc.titleDesign and analysis of a modified multiport interleaved flyback converter operated photovoltaic shunt active power filter pv shapf
dc.title.alternative
dc.type.degreePh.D.

Files

Original bundle

Now showing 1 - 5 of 12
Loading...
Thumbnail Image
Name:
01_title.pdf
Size:
95.72 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
02_prelim_pages.pdf
Size:
2.76 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
03_contents.pdf
Size:
122.21 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
04_abstracts.pdf
Size:
119.81 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
05_chapter1.pdf
Size:
347.67 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: