Numerical and experimental investigation and statistical studies of independent and combined effects of operating parameters catalyst to ionomer ratio and hot press load on PEMFC performance
Loading...
Date
item.page.authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Global warming, greenhouse gas emissions, and the rapid depletion
newlineof fossil fuel supplies have prompted the pursuit of renewable energy
newlinealternatives. Hydrogen energy makes Proton Exchange Membrane Fuel Cell
newline(PEMFC) one of the most promising renewable energy technologies for a
newlinesustainable energy source. PEMFC optimization is one of the most important
newlineareas for improved thermal and water management, which has an impact on
newlineefficiency; hence, current research is concentrated on this area. Operating
newlineparameters such as operating cell temperature, back pressure of reactant gas,
newlineinlet reactant gas relative humidity, nature of cathode gas, i.e., oxidant type,
newlineintake line temperature, and design parameters such as the ratio of catalyst to
newlineionomer and hot press load were analysed using numerical, experimental, and
newlinestatistical methods. Significant interaction effects were discovered between
newlineback pressure and input gas relative humidity (727 W/m2
newline) and between
newlineoperating cell temperature and intake relative humidity (545 W/m2
newline).
newlineExperiments revealed that a 3:1 ratio of catalyst to ionomer, a hot press load
newlineof 160 kg on a 6.5 cm2
newlineactive surface (0.15 mgpt per cm2 of active area), and
newlineoperating parameters of 100% RH, 333 K cell temperature, and 332 K intake
newlineline temperature were the optimal peak performance conditions for fabricated
newlineCatalyst Coated Membrane Electrode Assembly (CCM-MEA). In terms of
newlinemaximum power density, the fabricated, optimized MEA with PEMFC
newlineperformed 5.8% better than a commercially available PEMFC of equivalent
newlinesize. On the basis of numerical and experimental analysis as well as statistical
newlinecomparison, it was determined that the traditional statistical interaction effect
newlineequals half of the deviation value between the sum of independent effects and
newlinethe combined effect.