Non autonomous modelling of power systems and Development of Early warning indicators for instabilities

dc.contributor.guideGopalakrishnan E A
dc.coverage.spatial
dc.creator.researcherSuchithra K S
dc.date.accessioned2023-10-23T12:21:41Z
dc.date.available2023-10-23T12:21:41Z
dc.date.awarded2023
dc.date.completed2023
dc.date.registered2016
dc.description.abstractElectric power systems are one of the central systems for services such as drinking water, telecommunications and banking. The day-to-day increase in the power demand and lack of simultaneous infrastructure development compel power systems to operate close to the stability margin. Power systems operating close to the stability margin are vulnerable to transitions leading to instability. The intermittent nature of renewable energy resources exacerbates the instability issues. The power generation with renewable resources varies as a function of time, imparting non-autonomous nature to power systems. The stability analysis performed on the power systems considers the system as autonomous. However, the stability regimes of autonomous and non-autonomous systems are different. This creates the need for a non autonomous power system model which is simple enough to investigate the influence of rate dependent variation of system parameters on the stability characteristics. The power system is modelled as a non-autonomous system in the current thesis. Further, the stability characteristics of a non-autonomous power system model are investigated. Further, a comparative study of the stability regimes of autonomous and non-autonomous power system models is presented. The occurrence of subcritical Hopf bifurcation in the power system model was observed for the quasi-static variation of mechanical power. The rate-dependent variation in mechanical power showed a delay in the transition in the power system model. Next, depending on the rate of variation in mechanical power, early transitions with regard to the quasi-static Hopf point are observed. Furthermore, the relationship between the critical rate and the initial conditions is established. Even though the system is quasi-statically stable, systems that are undergoing sub-critical Hopf bifurcation can nevertheless be triggered to the other oscillatory state by noise. Therefore, it is important to investigate the effect of stochasticity and intermittency on the stability..
dc.description.note
dc.format.accompanyingmaterialNone
dc.format.dimensions
dc.format.extentxvii, 109
dc.identifier.urihttp://hdl.handle.net/10603/520530
dc.languageEnglish
dc.publisher.institutionDepartment of Electrical and Electronics Engineering
dc.publisher.placeCoimbatore
dc.publisher.universityAmrita Vishwa Vidyapeetham University
dc.relation
dc.rightsuniversity
dc.source.universityUniversity
dc.subject.keywordCB. EN.D*EEE16008; Electric power systems; Renewable Energy; electrical and electronics engineering
dc.subject.keywordEngineering and Technology
dc.titleNon autonomous modelling of power systems and Development of Early warning indicators for instabilities
dc.title.alternative
dc.type.degreePh.D.

Files

Original bundle

Now showing 1 - 5 of 12
Loading...
Thumbnail Image
Name:
01_title.pdf
Size:
300.64 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
02_preliminary page.pdf
Size:
904.88 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
03_contents.pdf
Size:
51.11 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
04_abstract.pdf
Size:
51.9 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
05_chapter 1.pdf
Size:
179.2 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: