Modification in Design of Artificially Roughened Solar air Heater for Enhancement of Heat Transfer Tate and Analysis of Fluid Flow

Abstract

The present research investigates the flow and heat transfer features of different kinds of newlineair impingement jet plates experimentally. Modification in design of artificially newlineroughened solar air heater has been done by the use of various air jet impingement plates, newlineincluding pentagonal, rectangular, square, and circular shapes, have been studied under newlinethe same Reynolds number. The hydraulic and thermal performance of different kinds of newlineimpingement jet plates are researched to determine the overall consequences. In terms of newlinehydraulic and thermal performance, the results show that impingement jet with circular newlineholes provides best outcomes than other equivalent impingement jet shapes. newlineThe highest absolute value of (Nucfoand#8260;Nuss) (fcfoand#8260;fss) newline newline0.33 and#8260; was 1.58, corresponding to a newlinerelative impingement jet diameter Dij/Dhy of 0.046, a relative pitch of jet in X-direction newline(Xijp/Dhy) of 0.305, relative pitch of jet in Y-direction (Yijp/Dhy) of 0.402. This study newlineinvestigates the use of cone frustum shaped roughness elements on the underside of the newlineabsorber plate with circular jet impingement in a solar air rectangular duct. Experiments newlineare being carried out to study turbulent fluid flow. The following parameters are included newlinein the impingement circular jets solar air heater testing: relative height of cone frustum newlineobstacle (Hcfo/Dhy) ranges between 0.064-0.119, ratio of inside flow diameter to inside newlinebase diameter (Dif/Dib) ranges from 1.08-1.92, ratio of outside diameter of cone frustum newlineobstacle to height of cone frustum obstacle (Do/Hcfo) between 1.39-2.23, relative pitch of newline newlineobstacle in X-direction (Xp/Do) ranges from 3.93-6.43. The relative pitch of obstacle in Y- newlinedirection (Yp/Do) between 3.21-5.65, the relative impingement jet diameter (Dij/Dhy), of newline newline0.046 and the Reynolds number (Re) ranges from 5,000 to 19,000. The relative pitch of newlinejet in X-direction (Xijp/Dhy) of 0.305, relative pitch of jet in Y-direction (Yijp/Dhy) of 0.402 newlineare used as stationary values. newlineExperiment was carried out to assess the hydraulic and thermal

Description

Keywords

Citation

item.page.endorsement

item.page.review

item.page.supplemented

item.page.referenced