Controllers based performance analysis of landsman converter multilevel inverter fed asynchronous motor

dc.contributor.guideSuresh Kumar, R
dc.coverage.spatialControllers based performance analysis of landsman converter multilevel inverter fed asynchronous motor
dc.creator.researcherNarendran, A
dc.date.accessioned2022-12-18T09:11:47Z
dc.date.available2022-12-18T09:11:47Z
dc.date.awarded2021
dc.date.completed2021
dc.date.registered
dc.description.abstractThe modern power electronics and power systems era is in early stages newlineof substantial high-tech opportunities for improving the current, voltage and newlinepower quality controller optimization process are evolved to improve the system newlineperformance. Many optimization algorithms are used to tune the controller newlineparameters. The current controller has a significant effect on the quality of the newlinecurrent supplied to the grid by the PV inverter, and therefore it is important that newlinethe controller provides a high quality sinusoidal output with minimal distortion newlineto avoid harmonics. In order to regulate the grid performance a single phase feed newlineback current loop is used. The two level inverter method is used for sustaining newlinepower from a scattered source to the network. newlineIn spite of, imbuing high powers into the network two level inverters newlineneed higher dc voltages with comprehensive power levels. Since the inverter newlineneeds to control high voltage and powers, the switches should have the choice to newlinewithstand high voltages and their speed of changes. Of course, the two level newlineinverters have enormous filtering requirements at high power production with newlinebreaking points. Henceforth, the amazing system supporting applications from newlinesuitable sources, MLI is evolving for attractive decision against the two level newlineinverters. newlineThe actual output speed from the asychronous motor is compared with newlinethe reference input speed. The calculated difference is named as error signal. newlineThis error output is given to the controller. The output from the controller is newlinegiven to the comparator which produces pulse width output. The width of pulse newlineapplied to the MOSFET of LC and the enhanced output is updated by the newlinecontroller. newline
dc.description.note
dc.format.accompanyingmaterialNone
dc.format.dimensions21cm
dc.format.extentxv,113p.
dc.identifier.urihttp://hdl.handle.net/10603/427401
dc.languageEnglish
dc.publisher.institutionFaculty of Electrical Engineering
dc.publisher.placeChennai
dc.publisher.universityAnna University
dc.relationp.105-112
dc.rightsuniversity
dc.source.universityUniversity
dc.subject.keywordLandsman converter
dc.subject.keywordInverter fed
dc.subject.keywordAsynchronous motor
dc.titleControllers based performance analysis of landsman converter multilevel inverter fed asynchronous motor
dc.title.alternative
dc.type.degreePh.D.

Files

Original bundle

Now showing 1 - 5 of 10
Loading...
Thumbnail Image
Name:
01_title.pdf
Size:
245.06 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
02_prelim pages.pdf
Size:
2.44 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
03_content.pdf
Size:
201.73 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
04_abstract.pdf
Size:
186.18 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
05_chapter 1.pdf
Size:
1.14 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: