P E E K at Implant Abutment Interface I A I

dc.contributor.guideLakshmi S
dc.coverage.spatial
dc.creator.researcherVigneswaran S
dc.date.accessioned2025-08-18T06:02:45Z
dc.date.available2025-08-18T06:02:45Z
dc.date.awarded2025
dc.date.completed2025
dc.date.registered2019
dc.description.abstractAn important consideration when choosing an implant system is the Implant Abutment Connection Interface. Polyetheretherketone is a promising substitute as abutments. This article aims to explore the characteristics of the IACI in PEEK abutments by investigating and comparing the tribocorrosion behavior of titanium implants paired with either PEEK or titanium abutments, as well as to assess microleakage at the implant abutment interface in titanium implants with PEEK abutments. Titanium implants featuring an 11 degree tapered conical connection with PEEK and Titanium abutments were chosen for the study. Open circuit potential and coefficient of friction measurements revealed that titanium implants with PEEK displayed stable and lower values as compared to that of titanium abutments. Wear surface analysis showed greater deterioration in titanium abutments, with visible wear patterns, while PEEK abutments showed smoother surfaces with minor grooves aligned with the sliding direction. Results of microleakage analysis indicated that under normal occlusal loads, no microleakage was observed in either titanium or PEEK abutment samples. But when occlusal loads exceeds the maximum range, PEEK abutments fractured, leading to microleakage, while titanium abutments didn t show leakage exhibiting a higher fracture resistance. Overall, we can conclude that, while PEEK showed potential in implant systems, further studies are required to assess in depth the durability and biocompatibility in clinical trials
dc.description.notePolyetheretherketone Tribocorrosion Microleakage
dc.format.accompanyingmaterialNone
dc.format.dimensions
dc.format.extentXIV 122
dc.identifier.researcherid0000-0002-1471-5002
dc.identifier.urihttp://hdl.handle.net/10603/657480
dc.languageEnglish
dc.publisher.institutionDepartment of Dentistry
dc.publisher.placeChennai
dc.publisher.universityMeenakshi Academy of Higher Education and Research
dc.relation
dc.rightsuniversity
dc.source.universityUniversity
dc.subject.keywordClinical Medicine
dc.subject.keywordClinical Pre Clinical and Health
dc.subject.keywordDentistry Oral Surgery and Medicine
dc.titleP E E K at Implant Abutment Interface I A I
dc.title.alternative
dc.type.degreePh.D.

Files

Original bundle

Now showing 1 - 5 of 12
Loading...
Thumbnail Image
Name:
01_title.pdf
Size:
161.72 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
02_prelim pages.pdf
Size:
629.63 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
03_content.pdf
Size:
162.67 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
04_abstract.pdf
Size:
237.86 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
05_chapter 1.pdf
Size:
373.43 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: