Enhancement of power quality Using fuzzy and anfis based Shunt active filter

dc.contributor.guidePadma Sen_US
dc.coverage.spatialEnhancement of power quality Using fuzzy and anfis based Shunt active filteren_US
dc.creator.researcherVenkatramanan C Ben_US
dc.date.accessioned2015-06-15T05:41:51Z
dc.date.available2015-06-15T05:41:51Z
dc.date.awarded30/04/2014en_US
dc.date.completed01/04/2014en_US
dc.date.issued2015-06-15
dc.date.registeredn.d,en_US
dc.description.abstractDue to increasing power demand the power system network newlinebecomes more and more complex one A survey shows that demand of power newlineincreases day by day As the demand increases the power networks are newlineoverloaded and power quality faces lot of struggle The power sag voltage newlineinstability harmonics distortion are the main causes of the above problem newlineFor solving the above problems we cannot go on installing new lines as it is newlinecost challenge To eliminate the causes of harmonics various techniques are newlinecontinuously introduced such as transformer connection introductions of newlinevarious type of filters etc newlineAmong all types of filters the Shunt Active Filter is popular due to newlineits advantageous characteristics The SAF maintains the sinusoidal newlinecharacteristics of the source current by injecting the opposite harmonics newlinedemanded by the load to the original harmonics produced by the load To newlineproduce opposite harmonics the SAF is connected in parallel with the load newlineThe objective of SAF is maintaining source current sinusoidal and in phase newlinewith source voltage As a result of this the Total Harmonic Distortion will be newlinezero and power factor will be unity Basically investigation of Cascaded Five newlineLevel Inverter CFLI is used in a SAF Making use of the CFLI has benefits newlineof low harmonics distortion reduced number of switches and switching newlinelosses newline newlineen_US
dc.description.notereference p151-158.en_US
dc.format.accompanyingmaterialNoneen_US
dc.format.dimensions23cm.en_US
dc.format.extentxx, 159p.en_US
dc.identifier.urihttp://hdl.handle.net/10603/43001
dc.languageEnglishen_US
dc.publisher.institutionFaculty of Electrical and Electronics Engineeringen_US
dc.publisher.placeChennaien_US
dc.publisher.universityAnna Universityen_US
dc.relationp151-158.en_US
dc.rightsuniversityen_US
dc.source.universityUniversityen_US
dc.subject.keywordCascaded Five Level Inverteren_US
dc.subject.keywordShunt Active Filteren_US
dc.titleEnhancement of power quality Using fuzzy and anfis based Shunt active filteren_US
dc.title.alternativeen_US
dc.type.degreePh.D.en_US

Files

Original bundle

Now showing 1 - 5 of 13
Loading...
Thumbnail Image
Name:
01_title.pdf
Size:
43.25 KB
Format:
Adobe Portable Document Format
Description:
Attached File
Loading...
Thumbnail Image
Name:
02_certificate.pdf
Size:
812.67 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
03_abstract.pdf
Size:
8.31 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
04_acknowledgement.pdf
Size:
6.23 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
05_content.pdf
Size:
65.22 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: