Studies on thermal management of lithium ion battery modules
Loading...
Date
item.page.authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
There has been a revolutionary transformation in battery energy
newlinestorage systems after the introduction of Lithium-Ion Batteries (LIBs) into the
newlinecommercial market. Today, LIBs are undisputedly the major source of power
newlinefor several interesting applications like the mobile phones, laptops, desktops,
newlineElectric Vehicles (EVs), and so on. LIBs have become very popular within a
newlineshort span of time due to superior qualities such as lightweight, high energy
newlinedensity, high power, large charge/discharge cycles, nil memory effect,
newlinenegligible self-discharge rate, compact design and so on. In spite of all the
newlinebenefits that LIBs offer, they have severe safety related issues due to excessive
newlineheat generation and overheating. Compared to its counterparts, LIBs generate
newlinea large amount of heat while under discharging/charging. The heat generated,
newlineresults in a significant rise in cell temperatures which lead to critical safety
newlineissues like Thermal Runaway (TR), Thermal Propagation (TP), firing and
newlineexplosion. Literature data shows that the recommended safe operating
newlinetemperature range of LIBs is about 20-40 and#8451;. For a safe operation, LIBs
newlinetherefore require efficient Battery Thermal Management Systems (BTMS) to
newlinecool the batteries and maintain their temperatures within the safe operating
newlinetemperature margin. Several studies have shown that LIBs generate a large
newlineamount of heat during discharging/fast charging at high C-rates. C-rates are
newlinegenerally defined as the rate at which current is drawn from or charged to the
newlinebatteries, w.r.t its nominal rating. For example, a 1C rating of a 1 Ah battery
newlinerepresents 1 A current being charged or discharged in 1 hour. A poor dissipation
newlineof heat could cause overheating of the batteries triggering TRs and internal
newlineshort-circuits. Temperatures during discharging of LIBs can reach about 70 and#8451;
newlinefor a 15 Ah LIB at 5C rates, whereas 50 and#8451; for a 40 Ah battery at 2C rates.
newlineDeveloping efficient BTMS is therefore crucial for the safe and reliable
newlineoperation of LIBs.
newline