Development of DNA biosensor for the detection of Leptospira interrogans causing leptospirosis

Abstract

xii newlineABSTRACT newlineLeptospirosis is a zoonotic infection which presents a wide range of symptoms in humans and is easily mistaken for other types of febrile illness. The diagnosis of leptospirosis involves the detection of L. interrogans, the causative agent in leptospirosis. The conventional methods for the detection of L. interrogans are bacterial culture, serology based methods such as enzyme linked immunosorbent assay (ELISA), macroscopic slide agglutination test (MSAT), immunofluorescence assay, indirect hemagglutination assay (IHA), latex agglutination, lateral flow assays (LFA) and polymerase chain reaction (PCR) etc. Another serological method Microscopic agglutination test (MAT) is considered to be the gold standard for leptospirosis diagnosis. No single test can be used for efficient diagnosis of leptospirosis and has to be supplemented by some other analysis. In the present study DNA based biosensor for the detection of Leptospira interrogans causing leptospirosis has been developed. newlineThe present study involves the development of PCR based genetic marker, nanohybrid biosensor and two nanocomposite based biosensors for the detection of L. interrogans. In the first experimental setup, a PCR based genetic marker based on LipL32 gene of L. interrogans was developed. LipL32 gene encodes for 32 kDa outer membrane lipoprotein highly conserved and expressed in pathogenic leptospires. The target gene was partially amplified using specific primers and the amplicon of 392 bp after gel electrophoresis and sequencing of the purified PCR product confirmed the amplification. newlineThe next experimental setup involves the development of nanohybrid electrochemical biosensor for the detection of L. interrogans. In this a gold nanoparticle embedded carboxylated multi-walled carbon nanotubes (nano-Au/c-MWCNTs) electrode was used for the development of nanohybrid biosensor. LipL32 gene based ssDNA probe was immobilized on the surface of nano-Au/c-MWCNTs electrode and hybridized with ssG-DNA of L. interrogans. The electrochemical changes on the electrode before and after hybridization were recorded using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with methylene blue (MB) as redox indicator. The sensitivity of the nanohybrid based biosensor was found 264.5 and#956;A cm-2 ng-1 and lower limit of detection (LOD) was observed 0.015 ng/6and#956;l newlinexiii newlinewith the regression coefficient (R2) of 0.97 using CV. The nanohybrid biosensor was characterized using scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR). Specificity of the developed nanohybrid biosensor with other pathogens was also checked and the developed nanohybrid biosensor was found stable for 6 months at 4°C with only 13% current loss as determined by DPV studies. newlineFurther, to increase the sensitivity of the nano-Au/c-MWCNTs based nanohybrid biosensor, two nanocomposites were fabricated on the surface of nano-Au/c-MWCNTs electrode. The first nanocomposite involved 4-aminothiophenol (ATP) and graphene quantum dots (GQD) conjugated on nano-Au/c-MWCNTs electrode surface using EDC: NHS cross linking chemistry. Thiol group of ATP was attached to the gold on the electrode surface and further GQD was attached to amine group of ATP through carboxyl moiety. The ssDNA probe was immobilized on electrode surface and hybridized with different concentrations of leptospiral ssG-DNA. CV and DPV studies were carried out for electrochemical analysis using MB as redox indicator. The sensitivity of the nano-Au/c-MWCNTs/ATP/GQD composite based biosensor was observed 603.8 and#956;A cm-2 ng-1and LOD was 0.0007 ng/6and#956;l with a regression coefficient (R2) of 0.84. The surface morphological changes which occurred on the electrode surface were recorded using field emission scanning electron microscopy (FE-SEM). The developed nanocomposite based biosensor was found specific for L. interrogans when analysed using CV with other pathogens and was stable upto 6 months at 4°C as determined by DPV analysis. newlineThe next nanocomposite was fabricated by using cysteine (Cys), polyamidoamine (PAMAM) and GQD in conjugation with nano-Au/c-MWCNTs electrode to form nano-Au/c-MWCNTs/Cys/PAMAM/GQD composite electrode. NH2 labeled ss-DNA probe of L. interrogans was immobilized on the nano-Au/c-MWCNTs/Cys/PAMAM/GQD composite electrode and was hybridized with different concentrations of L. interrogans ssG-DNA. CV and DPV studies were carried out to observe the electrochemical changes which occurred in the setup using MB as redox indicator. The sensitivity of the developed nano-Au/c-MWCNTs/Cys/PAMAM/GQD composite based biosensor was 1952.3and#956;A cm-2 ng-1and LOD was 0.112 pg/6and#956;l with a regression coefficient (R2) of 0.98. Validation of the developed biosensor with patient samples and comparison with other conventional methods for L. interrogans detection newlinexiv newlineand leptospirosis diagnosis was also done. It was found highly specific for L. interrogans and was sensitive than all the available conventional methods. newlineKeywords: Leptospirosis, Leptospira interrogans, LipL32, Sensitivity, Limit of detection, Nanohybrid biosensor, Nano-Au/c-MWCNTs/ATP/GQD composite, Nano-Au/c-MWCNTs/Cys/PAMAM/GQD composite, Validation, Comparison. newline

Description

Keywords

Citation

item.page.endorsement

item.page.review

item.page.supplemented

item.page.referenced